- Xxx - Other
- Wild T1a Theodolite Manual Pdf
- Wild T1a Theodolite Manual Download
- Wild T16 Theodolite Manual
Xxx - Other
Original Wild Heerbrugg Theodolite T1A Commercial Brochure This is an original A4 size Wild Heerbrugg illistrated booklet of sixteen pages with an explanation on everything there is to know about the T1A There is no reserve on this item.
Wild T1a Theodolite Manual Pdf
Wild T1a Theodolite Manual Download
Alignment with the help of the alignment service Nigel Warr 18th September 2015
Contents 1 Overview
2
2 The Leica AT401 Absolute Tracker
2
3 The CERN Coordinate System 3.1 Conversion from CERN to Miniball coordinate system . . . . . . . . . . . . . . . . . . . . . . 3.2 Conversion from Miniball to CERN coordinate system . . . . . . . . . . . . . . . . . . . . . .
2 4 4
4 Alignment of the frame
4
5 Alignment of the Coulex target chamber
6
6 Alignment of the targets
7
7 Alignment of the SPEDE target chamber
8
1
1
Overview
In the past, we used markings on the floor and on the wall behind the bending magnet before Miniball (viewed by opening a port-hole in the magnet) to set up the theodolite, so that it was directly over the point on the floor and looking at the point on the wall. This meant the theodolite was looking along the direction exactly opposite the beam direction. So if the target was centred on the crosshairs of the theodolite, it was correct. With HIE-ISOLDE it is no longer possible to open up a port-hole in the magnet and there is, in any case, no line of site to the wall and no mark on the wall. Instead there is a mark at the point where the beam intersects the wall after Miniball. There is also a mark on the floor after the beam dump. So in principle, we could mount the theodolite over the mark on the floor, line up to the one on the wall and rotate 180◦ and we would be looking also as before. Note that there are two ways to rotate the theodolite through 180◦ : • rotating about the vertical axis and using the scale to determine the number of degrees to rotate • rotating just the telescope about the horizontal axis and using the spirit level to get it level before and after the rotation. However, in 2015, we tried a new method for aligning, with the help of the alignment people (Michal Rebisz, Antje Behrens and Benoit Cummer). This new method is described in this document.
2
The Leica AT401 Absolute Tracker
The alignment service have a Leica AT401 Absolute Tracker, which is first set up using known points fixed in the floor and walls at ISOLDE, where they mount prisms and the AT401 uses a laser to determine is position relative to these points. After that, they can place a prism at any point and determine its absolute position in the CERN Coordinate System.
3
The CERN Coordinate System
The CERN Coordinate System has its origin at the PS, but there are offsets of about 2 km added to each coordinate, so it cannot be confused with any other system. The coordinates are either given as xCCS , yCCS , and zCCS or xCCS , yCCS , and HCCS . The relationship between zCCS and HCCS is given by:
zCCS = HCCS + 2000.00079 −
d2 2(R + h)
where
d=
p
(xCCS − 2000)2 + (yCCS − 2097.7927)2
and R is the mean radius of the earth in metres given by
R = 6371000 To go in the other direction, we use 0010
hCCS
zCCS − 2000.00079 + 0001 = d cos R
d2 2R
0011
Using the MADX calculation from 15/06/2015, which is in version 1.1 of the EDMS document 1323585 (https://edms.cern.ch/document/1323585/1.1) in the file XT01 survey ccs.txt. we have the coordinates of the Miniball target position:
x=1864.28940, y=2282.82486, z=2437.48881, h=437.49215 [m] 2
Figure 1: The Leica AT401 Absolute Tracker.
3
We define a Miniball coordinate system with the origin at the nominal target position, the y direction in the direction of the beam and the z-direction vertically upwards. So the z-axis is in the same direction as that of the CERN one, but it is rotated by -257.85485997◦ = -4.5004162987 radians1 , relative to the CERN coordinate system. Note, however, that we use millimetres not metres.
Angle between coordinate systems = -257.85485997◦ = -4.5004162987 radians Note that the Miniball CAD diagram is offset by 25 mm relative to the Miniball coordinate system. This is because it was designed for a nominal beam height of 1750 mm, but at ISOLDE the beam height is nominally at 1725 mm.
3.1
Conversion from CERN to Miniball coordinate system xM B =
1000 · (0.97761779 · (yCCS − 2282.824858) − 0.21038884 · (xCCS − 1864.289396))
yM B =
1000 · (−0.97761779 · (xCCS − 1864.289396) − 0.21038884 · (yCCS − 2282.824858))
zM B =
1000 · (zCCS − 2437.488812)
or 1000 · (HCCS − 437.492155)
zM B = where
0.97761779 = sin(−257.854860◦ ) 0.21038884 = cos(−257.854860◦ ) where the values with the CCS subscript are in the CERN Coordinate System and those with the MB subscript are in the Miniball coordinate system. The Miniball coordinate system has its origin at the nominal target position, with the y direction representing the beam and x horiziontal and z vertical.
3.2
4
Conversion from Miniball to CERN coordinate system xCCS =
1864.289396 − 0.97761779 · yM B /1000 − 0.21038884 · xM B /1000
yCCS =
2282.824858 + 0.97761779 · xM B /1000 − 0.21038884 · yM B /1000
zCCS =
zM B /1000 + 2437.488812
HCCS =
zM B /1000 + 437.492155
Alignment of the frame
To align the frame, we determined the absolute coordinates of the rings onto which the arcs are attached. There are three such rings below the target chamber and three above,on each side. By measuring at least three points on a ring, they can fit a circle and determine the centre of the circle. This should be exactly below or above the nominal target position. From the CAD diagrams, we know the positions of the centre of the top and bottom faces of each ring. If we number the rings from top to bottom, so the highest ring is ring 1 and the lowest is ring 12, we have the following coordinates for the centre of the top and bottom flat surfaces of each ring: 1 Angle
also taken from EDMS document 1323585
4
Figure 2: The Miniball frame, showing the 12 rings (bright green), numbered 1 to 12 from top to bottom. The beam goes into the page from left to right. Ring 1 1 2 2 3 3 4 4 5 5 6 6 7 7 8 8 9 9 10 10 11 11 12 12
Surface Top Bottom Top Bottom Top Bottom Top Bottom Top Bottom Top Bottom Top Bottom Top Bottom Top Bottom Top Bottom Top Bottom Top Bottom
xM B , yM B , zM B [mm] 0, 0, +835 0, 0, +795 0, 0, +795 0, 0, +755 0, 0, +755 0, 0, +717 0, 0, +585 0, 0, +547 0, 0, +547 0, 0, +507 0, 0, +507 0, 0, +467 0, 0, -473 0, 0, -513 0, 0, -513 0, 0, -552 0, 0, -552 0, 0, -591 0, 0, -723 0, 0, -761 0, 0, -761 0, 0, -801 0, 0, -801 0, 0, -841
xCCS , yCCS , zCCS , HCCS [m] 1864.28940, 2282.82486, 2438.32381, 438.32715 1864.28940, 2282.82486, 2438.28381, 438.28715 1864.28940, 2282.82486, 2438.28381, 438.28715 1864.28940, 2282.82486, 2438.24381, 438.24715 1864.28940, 2282.82486, 2438.24381, 438.24715 1864.28940, 2282.82486, 2438.20581, 438.20915 1864.28940, 2282.82486, 2438.07381, 438.07715 1864.28940, 2282.82486, 2438.03581, 438.03915 1864.28940, 2282.82486, 2438.03581, 438.03915 1864.28940, 2282.82486, 2437.99581, 437.99915 1864.28940, 2282.82486, 2437.99581, 437.99915 1864.28940, 2282.82486, 2437.95581, 437.95915 1864.28940, 2282.82486, 2437.01581, 437.01915 1864.28940, 2282.82486, 2436.97581, 436.97915 1864.28940, 2282.82486, 2436.97581, 436.97915 1864.28940, 2282.82486, 2436.93681, 436.94015 1864.28940, 2282.82486, 2436.93681, 436.94015 1864.28940, 2282.82486, 2436.89781, 436.90115 1864.28940, 2282.82486, 2436.76581, 436.76915 1864.28940, 2282.82486, 2436.72781, 436.73115 1864.28940, 2282.82486, 2436.72781, 436.73115 1864.28940, 2282.82486, 2436.68781, 436.69115 1864.28940, 2282.82486, 2436.68781, 436.69115 1864.28940, 2282.82486, 2436.64781, 436.65115
Note, however, that these values are only achieved if the ball is closed and the locking pins are in place. However, it is rather hard to measure in this configuration, so it may be necessary to compromise. The rings above the target chamber are most affected by the absence of the locking pins.
5
5
Alignment of the Coulex target chamber
Miniball Coulex target chamber Beam direction
10
11 3
2
12
9
Coordinates relative to
CERN Coordinates System in m:
to centre in mm: 0
= (0,
1
0,
0)
0
(1864.2894, 2282.8249,
437.4922)
= (-137.5, -367.5, 100)
1
(1864.6776, 2282.7678,
437.5921)
2
= (-137.5, +367.5, 100)
2
(1863.9590, 2282.6131,
437.5922)
3
= (+137.5, -367.5, 100)
3
(1864.6197, 2283.0366,
437.5922)
4
= (+137.5, +367.5, 100)
4
(1863.9012, 2282.8820,
437.5922)
5
= (-127.5, -367.5, 100)
5
(1864.6755, 2282.7775,
437.5921)
6
= (-127.5, -351.5, 100)
6
(1864.6599, 2282.7742,
437.5921)
7
= (+127.5, -351.5, 100)
7
(1864.6062, 2283.0235,
437.5922)
8
= (+127.5, -367.5, 100)
8
(1864.6218, 2283.0268,
437.5922)
9
= (-127.5, +351.5, 100)
9
(1863.9726, 2282.6263,
437.5922)
10 = (-127.5, +367.5, 100)
10 (1863.9569, 2282.6229,
437.5922)
11 = (+127.5, +367.5, 100)
11 (1863.9033, 2282.8722,
437.5922)
12 = (+127.5, +351.5, 100)
12 (1863.9189, 2282.8756,
437.5922)
0
6
7 4
1 5
8
Figure 3: The target chamber alignment There are two ways to determine the alignment of the chamber:
6
Figure 4: The Leica retro-reflective targets mounted on the Miniball target wheel • Using the upper corners of the front and back plates • Using the sphere of the chamber itself The former method relies on the information in figure 3. In practise, it is not possible to use the points on the side plates, as there is a small difference depending how the side plates are mounted. However, you must have the side plates on to change the alignment, otherwise you could damage the target chamber. So it is really points 6, 7, 9 and 12 which need to be used. Point (See fig. 3) 6 7 9 12
xM B , yM B , zM B [mm] -127.5, -351.5, 100 +127.5, -351.5, 100 -127.5, +351.5, 100 +127.5, +351.5, 100
xCCS , yCCS , zCCS , HCCS [m] 1864.65985, 2282.77416, 2437.48881, 437.59215 1864.60620, 2283.02346, 2437.48881, 437.59215 1863.97259, 2282.62626, 2437.48881, 437.59215 1863.91894, 2282.87555, 2437.48881, 437.59215
The latter method involves measuring several points on the outer surface of the sphere and fitting a sphere to those points. For this, the side plates need to be removed (at least on one side), so it is not feasible to adjust the chamber this way, but it is a good check after using the other method.
6
Alignment of the targets
There are two ways to do this: • set up the theodolite so that it is looking in the inverse direction of the beam and check the crosshairs of the theodolite are centred on the target • use the absolute method with some special Leica retro-reflective targets (see fig. 4) mounted on the target wheel. 7
The former method has the disadvantage that it doesn’t measure the offset of the target along the beam direction. The nominal target position is2 : Point (See fig. 3) 0
7
xM B , yM B , zM B [mm] 0, 0, 0
xCCS , yCCS , zCCS , HCCS [m] 1864.28940, 2282.82486, 2437.48881, 437.49215
Alignment of the SPEDE target chamber
Figure 5: The SPEDE chamber The SPEDE target chamber is 27 mm longer than the Coulex one. As with the Coulex chamber, the target is centred between the two flanges, which are compatible with the Coulex ones. The points in the following table correspond to points 0, 5-11 in 3. i.e. without the side plates. The width (±127.5 mm) is the same, but the lengths (±365 and ±381 mm) are longer than those of the Coulex chamber (±351.5 and ±367.5 mm). Point (See fig. 5) 0 1 2 3 4 5 6 7 8
2 The
xM B , yM B , zM B [mm] 0.00, 0.00, 0.00 -127.50, -381.00, 80.00 -127.50, 381.00, 80.00 127.50, -381.00, 80.00 127.50, 381.00, 80.00 -127.50, -365.00, 80.00 -127.50, 365.00, 80.00 127.50, -365.00, 80.00 127.50, 365.00, 80.00
xCCS , yCCS , zCCS , HCCS [m] 1864.28940, 2282.82486, 2437.48881, 437.49215 1864.68869, 2282.78037, 2437.56881, 437.57214 1863.94375, 2282.62005, 2437.56881, 437.57216 1864.63504, 2283.02966, 2437.56881, 437.57215 1863.89010, 2282.86935, 2437.56881, 437.57216 1864.67305, 2282.77700, 2437.56881, 437.57214 1863.95939, 2282.62342, 2437.56881, 437.57216 1864.61940, 2283.02630, 2437.56881, 437.57215 1863.90574, 2282.87271, 2437.56881, 437.57216
nominal target position is taken from version 1.1 of the EDMS document 1323585.
8
Contents 1 Overview
2
2 The Leica AT401 Absolute Tracker
2
3 The CERN Coordinate System 3.1 Conversion from CERN to Miniball coordinate system . . . . . . . . . . . . . . . . . . . . . . 3.2 Conversion from Miniball to CERN coordinate system . . . . . . . . . . . . . . . . . . . . . .
2 4 4
4 Alignment of the frame
4
5 Alignment of the Coulex target chamber
6
6 Alignment of the targets
7
7 Alignment of the SPEDE target chamber
8
1
1
Overview
In the past, we used markings on the floor and on the wall behind the bending magnet before Miniball (viewed by opening a port-hole in the magnet) to set up the theodolite, so that it was directly over the point on the floor and looking at the point on the wall. This meant the theodolite was looking along the direction exactly opposite the beam direction. So if the target was centred on the crosshairs of the theodolite, it was correct. With HIE-ISOLDE it is no longer possible to open up a port-hole in the magnet and there is, in any case, no line of site to the wall and no mark on the wall. Instead there is a mark at the point where the beam intersects the wall after Miniball. There is also a mark on the floor after the beam dump. So in principle, we could mount the theodolite over the mark on the floor, line up to the one on the wall and rotate 180◦ and we would be looking also as before. Note that there are two ways to rotate the theodolite through 180◦ : • rotating about the vertical axis and using the scale to determine the number of degrees to rotate • rotating just the telescope about the horizontal axis and using the spirit level to get it level before and after the rotation. However, in 2015, we tried a new method for aligning, with the help of the alignment people (Michal Rebisz, Antje Behrens and Benoit Cummer). This new method is described in this document.
2
The Leica AT401 Absolute Tracker
The alignment service have a Leica AT401 Absolute Tracker, which is first set up using known points fixed in the floor and walls at ISOLDE, where they mount prisms and the AT401 uses a laser to determine is position relative to these points. After that, they can place a prism at any point and determine its absolute position in the CERN Coordinate System.
3
The CERN Coordinate System
The CERN Coordinate System has its origin at the PS, but there are offsets of about 2 km added to each coordinate, so it cannot be confused with any other system. The coordinates are either given as xCCS , yCCS , and zCCS or xCCS , yCCS , and HCCS . The relationship between zCCS and HCCS is given by:
zCCS = HCCS + 2000.00079 −
d2 2(R + h)
where
d=
p
(xCCS − 2000)2 + (yCCS − 2097.7927)2
and R is the mean radius of the earth in metres given by
R = 6371000 To go in the other direction, we use 0010
hCCS
zCCS − 2000.00079 + 0001 = d cos R
d2 2R
0011
Using the MADX calculation from 15/06/2015, which is in version 1.1 of the EDMS document 1323585 (https://edms.cern.ch/document/1323585/1.1) in the file XT01 survey ccs.txt. we have the coordinates of the Miniball target position:
x=1864.28940, y=2282.82486, z=2437.48881, h=437.49215 [m] 2
Figure 1: The Leica AT401 Absolute Tracker.
3
We define a Miniball coordinate system with the origin at the nominal target position, the y direction in the direction of the beam and the z-direction vertically upwards. So the z-axis is in the same direction as that of the CERN one, but it is rotated by -257.85485997◦ = -4.5004162987 radians1 , relative to the CERN coordinate system. Note, however, that we use millimetres not metres.
Angle between coordinate systems = -257.85485997◦ = -4.5004162987 radians Note that the Miniball CAD diagram is offset by 25 mm relative to the Miniball coordinate system. This is because it was designed for a nominal beam height of 1750 mm, but at ISOLDE the beam height is nominally at 1725 mm.
3.1
Conversion from CERN to Miniball coordinate system xM B =
1000 · (0.97761779 · (yCCS − 2282.824858) − 0.21038884 · (xCCS − 1864.289396))
yM B =
1000 · (−0.97761779 · (xCCS − 1864.289396) − 0.21038884 · (yCCS − 2282.824858))
zM B =
1000 · (zCCS − 2437.488812)
or 1000 · (HCCS − 437.492155)
zM B = where
0.97761779 = sin(−257.854860◦ ) 0.21038884 = cos(−257.854860◦ ) where the values with the CCS subscript are in the CERN Coordinate System and those with the MB subscript are in the Miniball coordinate system. The Miniball coordinate system has its origin at the nominal target position, with the y direction representing the beam and x horiziontal and z vertical.
3.2
4
Conversion from Miniball to CERN coordinate system xCCS =
1864.289396 − 0.97761779 · yM B /1000 − 0.21038884 · xM B /1000
yCCS =
2282.824858 + 0.97761779 · xM B /1000 − 0.21038884 · yM B /1000
zCCS =
zM B /1000 + 2437.488812
HCCS =
zM B /1000 + 437.492155
Alignment of the frame
To align the frame, we determined the absolute coordinates of the rings onto which the arcs are attached. There are three such rings below the target chamber and three above,on each side. By measuring at least three points on a ring, they can fit a circle and determine the centre of the circle. This should be exactly below or above the nominal target position. From the CAD diagrams, we know the positions of the centre of the top and bottom faces of each ring. If we number the rings from top to bottom, so the highest ring is ring 1 and the lowest is ring 12, we have the following coordinates for the centre of the top and bottom flat surfaces of each ring: 1 Angle
also taken from EDMS document 1323585
4
Figure 2: The Miniball frame, showing the 12 rings (bright green), numbered 1 to 12 from top to bottom. The beam goes into the page from left to right. Ring 1 1 2 2 3 3 4 4 5 5 6 6 7 7 8 8 9 9 10 10 11 11 12 12
Surface Top Bottom Top Bottom Top Bottom Top Bottom Top Bottom Top Bottom Top Bottom Top Bottom Top Bottom Top Bottom Top Bottom Top Bottom
xM B , yM B , zM B [mm] 0, 0, +835 0, 0, +795 0, 0, +795 0, 0, +755 0, 0, +755 0, 0, +717 0, 0, +585 0, 0, +547 0, 0, +547 0, 0, +507 0, 0, +507 0, 0, +467 0, 0, -473 0, 0, -513 0, 0, -513 0, 0, -552 0, 0, -552 0, 0, -591 0, 0, -723 0, 0, -761 0, 0, -761 0, 0, -801 0, 0, -801 0, 0, -841
xCCS , yCCS , zCCS , HCCS [m] 1864.28940, 2282.82486, 2438.32381, 438.32715 1864.28940, 2282.82486, 2438.28381, 438.28715 1864.28940, 2282.82486, 2438.28381, 438.28715 1864.28940, 2282.82486, 2438.24381, 438.24715 1864.28940, 2282.82486, 2438.24381, 438.24715 1864.28940, 2282.82486, 2438.20581, 438.20915 1864.28940, 2282.82486, 2438.07381, 438.07715 1864.28940, 2282.82486, 2438.03581, 438.03915 1864.28940, 2282.82486, 2438.03581, 438.03915 1864.28940, 2282.82486, 2437.99581, 437.99915 1864.28940, 2282.82486, 2437.99581, 437.99915 1864.28940, 2282.82486, 2437.95581, 437.95915 1864.28940, 2282.82486, 2437.01581, 437.01915 1864.28940, 2282.82486, 2436.97581, 436.97915 1864.28940, 2282.82486, 2436.97581, 436.97915 1864.28940, 2282.82486, 2436.93681, 436.94015 1864.28940, 2282.82486, 2436.93681, 436.94015 1864.28940, 2282.82486, 2436.89781, 436.90115 1864.28940, 2282.82486, 2436.76581, 436.76915 1864.28940, 2282.82486, 2436.72781, 436.73115 1864.28940, 2282.82486, 2436.72781, 436.73115 1864.28940, 2282.82486, 2436.68781, 436.69115 1864.28940, 2282.82486, 2436.68781, 436.69115 1864.28940, 2282.82486, 2436.64781, 436.65115
Note, however, that these values are only achieved if the ball is closed and the locking pins are in place. However, it is rather hard to measure in this configuration, so it may be necessary to compromise. The rings above the target chamber are most affected by the absence of the locking pins.
5
5
Alignment of the Coulex target chamber
Miniball Coulex target chamber Beam direction
10
11 3
2
12
9
Coordinates relative to
CERN Coordinates System in m:
to centre in mm: 0
= (0,
1
0,
0)
0
(1864.2894, 2282.8249,
437.4922)
= (-137.5, -367.5, 100)
1
(1864.6776, 2282.7678,
437.5921)
2
= (-137.5, +367.5, 100)
2
(1863.9590, 2282.6131,
437.5922)
3
= (+137.5, -367.5, 100)
3
(1864.6197, 2283.0366,
437.5922)
4
= (+137.5, +367.5, 100)
4
(1863.9012, 2282.8820,
437.5922)
5
= (-127.5, -367.5, 100)
5
(1864.6755, 2282.7775,
437.5921)
6
= (-127.5, -351.5, 100)
6
(1864.6599, 2282.7742,
437.5921)
7
= (+127.5, -351.5, 100)
7
(1864.6062, 2283.0235,
437.5922)
8
= (+127.5, -367.5, 100)
8
(1864.6218, 2283.0268,
437.5922)
9
= (-127.5, +351.5, 100)
9
(1863.9726, 2282.6263,
437.5922)
10 = (-127.5, +367.5, 100)
10 (1863.9569, 2282.6229,
437.5922)
11 = (+127.5, +367.5, 100)
11 (1863.9033, 2282.8722,
437.5922)
12 = (+127.5, +351.5, 100)
12 (1863.9189, 2282.8756,
437.5922)
0
6
7 4
1 5
8
Figure 3: The target chamber alignment There are two ways to determine the alignment of the chamber:
6
Figure 4: The Leica retro-reflective targets mounted on the Miniball target wheel • Using the upper corners of the front and back plates • Using the sphere of the chamber itself The former method relies on the information in figure 3. In practise, it is not possible to use the points on the side plates, as there is a small difference depending how the side plates are mounted. However, you must have the side plates on to change the alignment, otherwise you could damage the target chamber. So it is really points 6, 7, 9 and 12 which need to be used. Point (See fig. 3) 6 7 9 12
xM B , yM B , zM B [mm] -127.5, -351.5, 100 +127.5, -351.5, 100 -127.5, +351.5, 100 +127.5, +351.5, 100
xCCS , yCCS , zCCS , HCCS [m] 1864.65985, 2282.77416, 2437.48881, 437.59215 1864.60620, 2283.02346, 2437.48881, 437.59215 1863.97259, 2282.62626, 2437.48881, 437.59215 1863.91894, 2282.87555, 2437.48881, 437.59215
The latter method involves measuring several points on the outer surface of the sphere and fitting a sphere to those points. For this, the side plates need to be removed (at least on one side), so it is not feasible to adjust the chamber this way, but it is a good check after using the other method.
6
Alignment of the targets
There are two ways to do this: • set up the theodolite so that it is looking in the inverse direction of the beam and check the crosshairs of the theodolite are centred on the target • use the absolute method with some special Leica retro-reflective targets (see fig. 4) mounted on the target wheel. 7
The former method has the disadvantage that it doesn’t measure the offset of the target along the beam direction. The nominal target position is2 : Point (See fig. 3) 0
7
xM B , yM B , zM B [mm] 0, 0, 0
xCCS , yCCS , zCCS , HCCS [m] 1864.28940, 2282.82486, 2437.48881, 437.49215
Alignment of the SPEDE target chamber
Figure 5: The SPEDE chamber The SPEDE target chamber is 27 mm longer than the Coulex one. As with the Coulex chamber, the target is centred between the two flanges, which are compatible with the Coulex ones. The points in the following table correspond to points 0, 5-11 in 3. i.e. without the side plates. The width (±127.5 mm) is the same, but the lengths (±365 and ±381 mm) are longer than those of the Coulex chamber (±351.5 and ±367.5 mm). Point (See fig. 5) 0 1 2 3 4 5 6 7 8
2 The
xM B , yM B , zM B [mm] 0.00, 0.00, 0.00 -127.50, -381.00, 80.00 -127.50, 381.00, 80.00 127.50, -381.00, 80.00 127.50, 381.00, 80.00 -127.50, -365.00, 80.00 -127.50, 365.00, 80.00 127.50, -365.00, 80.00 127.50, 365.00, 80.00
xCCS , yCCS , zCCS , HCCS [m] 1864.28940, 2282.82486, 2437.48881, 437.49215 1864.68869, 2282.78037, 2437.56881, 437.57214 1863.94375, 2282.62005, 2437.56881, 437.57216 1864.63504, 2283.02966, 2437.56881, 437.57215 1863.89010, 2282.86935, 2437.56881, 437.57216 1864.67305, 2282.77700, 2437.56881, 437.57214 1863.95939, 2282.62342, 2437.56881, 437.57216 1864.61940, 2283.02630, 2437.56881, 437.57215 1863.90574, 2282.87271, 2437.56881, 437.57216
nominal target position is taken from version 1.1 of the EDMS document 1323585.
8
Wild T16 Theodolite Manual
- The addition of the compensator resulted in the new type name 'T1A', where the A stands for 'Automatic', followed by the T1A-E - 'E' for the 'Erect' field of view - in 1959 (the one shown here is a T1A, see adjacent picture and figure 11). 2 It was the first Wild theodolite - and perhaps the first theodolite at all - to feature an automatic.
- File Type PDF Wild T1a Theodolite Manual Wild T1a Theodolite Manual Thank you definitely much for downloading wild t1a theodolite manual.Maybe you have knowledge that, people have see numerous time for their favorite books later than this wild t1a theodolite manual, but end occurring in harmful downloads.